We offer over 100 million lbs of annual production capacity, 
which is continuously evaluated and enhanced with increasing demand.

At Jain Chem, we continually update our reactors so that you receive the highest quality products to meet your specific needs.

  • Operating 24 Hours x 5 Days/Week
  • 70,000 sq.ft. Under Roof
  • 27 Vessels from 10 gal to 7700 gal
  • High Temperature Reactions (to 500°F-260°C)
  • Pressure Reactions (to 150 psi)
  • Over 100,000 gal of Bulk Storage Under Roof
  • 10 Chemists on Staff
  • Pilot Plant
  • Packaging in Bulk, Totes and Drums
Reactor/Blender Capacity Gal Type Pressure Rating Max Temperature Condenser Miscellaneous
#1 750 304 SS Full vacuum to 75 psi 500°F Single Stage Internal coils for heating and cooling, Hot Oil on Jacket
#202 3500 304 SS Full vacuum to 100 psi 500°F Two Stage Heating and cooling with oil on the Jacket
#3 500 304 SS 15 psi 365°F None Cooling water and steam on the Jacket
#4A 2000 Reinforced Fiberglass Atmospheric Ambient None Internal coils for cooling
#4B 3000 Reinforced Fiberglass Atmospheric Ambient None Internal coils for cooling
#6 750 Glass Lined Full Vacuum to 25 psi 365°F Single Stage Cooling water and steam on the Jacket
#7 1000 304 SS Full Vacuum to 50 psi 365°F Single Stage Cooling water and steam on the Jacket
#8 3500 304 SS Full Vacuum to 15 psi 250°F Single Stage Internal Coils for heating and cooling
#10 3000 Steel, epoxy lined Atmospheric Ambient None High viscosity blending
#11 2000 304 SS Full vacuum to 100 psi 365°F Two Stage Cooling water and steam on the Jacket
#13 7000 304 SS Atmospheric Ambient None High viscosity blending
#14 6000 304 SS Full vacuum to 100 psi 365°F Two Stage Cooling water and steam on the Jacket
#15 3500 304 SS Full vacuum to 150 psi 400°F Single Stage Cooling water and steam on the Jacket
#16 3000 304 SS Atmospheric Ambient None High viscosity blending
#17 6000 304 SS Full vacuum to 150 psi 400°F Two Stage Cooling water and steam on the Jacket
#215 7700 304 SS Atmospheric 365° F None Internal coils and direct steam injection for heating, internal coils for cooling
SD-1 4800 304 SS Atmospheric 365°F None Internal coils and direct steam injection for heating, internal coils for cooling
SD-2 4800 304 SS Atmospheric 365°F None Internal coils and direct steam injection for heating, internal coils for cooling
#104 2700 304 SS Atmospheric 365°F None Jacket and direct steam injection for heating, jacket for cooling
LD-1 1400 304 SS Atmospheric 200°F None Jacketed Cowles Mixers
LD-2 1400 304 SS Atmospheric 200°F None Jacketed Cowles Mixers
PP-1 200 304 SS Full Vacuum to 25 psi 365°F Single Stage Pilot plant reactor
PP-2 100 Glass Lined Atmospheric 365°F None Pilot plant reactor
PP-3 10 304 SS 100 psi 550°F Single Stage Internal coils for heating and cooling. Electric mantle for high temperture
DRY BLENDER 1 6000 LB 304 SS Atmospheric Operated below 300°F None Heating and cooling with oil on the Jacket
DRY BLENDER 2 6000 LB 304 SS Atmospheric Operated below 300°F None Heating and cooling with oil on the Jacket
DRY BLENDER 5 6000 LB 304 SS Atmospheric Operated below 300°F None Cooling water and steam on the Jacket